| موضوع: جدولة كاملة لبلوكات الوظائف الخاصة في s7-300 الجمعة 10 ديسمبر 2010 - 14:29 | |
| System Function Blocks Number Name Family Description SFB 0 CTU IEC_TC Count Up SFB 1 CTD IEC_TC Count Down SFB 2 CTUD IEC_TC Count Up/Down SFB 3 TP IEC_TC Generate a Pulse SFB 4 TON IEC_TC Generate an On Delay SFB 5 TOF IEC_TC Generate an Off Delay SFB 8 USEND COM_FUNC Uncoordinated Sending of Data SFB 9 URCV COM_FUNC Uncoordinated Receiving of Data SFB 12 BSEND COM_FUNC Sending Segmented Data SFB 13 BRCV COM_FUNC Receiving Segmented Data SFB 14 GET COM_FUNC Read Data from a Remote CPU SFB 15 PUT COM_FUNC Write Data to a Remote CPU SFB 16 PRINT COM_FUNC Send Data to Printer SFB 19 START COM_FUNC Initiate a Warm or Cold Restart on a Remote Device SFB 20 STOP COM_FUNC Changing a Remote Device to the STOP State SFB 21 RESUME COM_FUNC Initiate a Hot Restart on a Remote Device SFB 22 STATUS COM_FUNC Query the Status of a Remote Partner SFB 23 USTATUS COM_FUNC Receive the Status of a Remote Device SFB 29 HS_COUNT COUNTERS Counter (high-speed counter, integrated function) (only exist on the CPU 312 IFM and CPU 314 IFM) SFB 30 FREQ_MES COUNTERS Frequency Meter (frequency meter, integrated function (only exist on the CPU 312 IFM and CPU 314 IFM) SFB 31 NOTIFY_8P COM_FUNC Generating block related messages without acknowledgement indication SFB 32 DRUM TIMERS Implement a Sequencer SFB 33 ALARM COM_FUNC Generate Block-Related Messages with Acknowledgment Display SFB 34 ALARM_8 COM_FUNC Generate Block-Related Messages without Values for 8 Signals SFB 35 ALARM_8P COM_FUNC Generate Block-Related Messages with Values for 8 Signals SFB 36 NOTIFY COM_FUNC Generate Block-Related Messages without Acknowledgment Display SFB 37 AR_SEND COM_FUNC Send Archive Data SFB 38 HSC_A_B COUNTERS Counter A/B (integrated function) (only exist on the CPU 314 IFM) SFB 39 POS ICONT Position (integrated function) (only exist on the CPU 314 IFM) SFB 41 CONT_C ICONT Continuous Control (only exist on the CPU 314 IFM) SFB 42 CONT_S ICONT Step Control (only exist on the CPU 314 IFM) SFB 43 PULSEGEN ICONT Pulse Generation (only exist on the CPU 314 IFM) SFB 44 ANALOG TEC_FUNC Positioning with Analog Output (only exist on the S7-300C CPUs) SFB 46 DIGITAL TEC_FUNC Positioning with Digital Output (only exist on the S7-300C CPUs) SFB 47 COUNT TEC_FUNC Controlling the Counter (only exist on the S7-300C CPUs) SFB 48 FREQUENC TEC_FUNC Controlling the Frequency Measurement (only exist on the S7-300C CPUs) SFB 49 PULSE TEC_FUNC Controlling Pulse Width Modulation (only exist on the S7-300C CPUs) SFB 52 RDREC DP Reading a Data Record SFB 53 WRREC DP Writing a Data Record SFB 54 RALRM DP Receiving an Interrupt SFB 60 SEND_PTP TEC_FUNC Sending Data (ASCII, 3964(R)) (only exist on the S7-300C CPUs) SFB 61 RECV_PTP TEC_FUNC Receiving Data (ASCII, 3964(R)) (only exist on the S7-300C CPUs) SFB 62 RES_RECV TEC_FUNC Deleting the Receive Buffer (ASCII, 3964(R)) (only exist on the S7-300C CPUs) SFB 63 SEND_RK TEC_FUNC Sending Data (RK 512) (only exist on the S7-300C CPUs) SFB 64 FETCH_RK TEC_FUNC Fetching Data (RK 512) (only exist on the S7-300C CPUs) SFB 65 SERVE_RK TEC_FUNC Receiving and Providing Data (RK 512) (only exist on the S7-300C CPUs) SFB 75 SALRM DP Send interrupt to DP master SFB 81 RD_DPAR IO_FUNCT Read Predefined Parameter
System Function Calls Number Name Family Description SFC 0 SET_CLK CLK_FUNC Set System Clock SFC 1 READ_CLK CLK_FUNC Read System Clock SFC 2 SET_RTM CLK_FUNC Set Run-time Meter SFC 3 CTRL_RTM CLK_FUNC Start/Stop Run-time Meter SFC 4 READ_RTM CLK_FUNC Read Run-time Meter SFC 5 GADR_LGC IO_FUNCT Query Logical Address of a Channel SFC 6 RD_SINFO DB_FUNCT Read OB Start Information SFC 7 DP_PRAL DP Trigger a Hardware Interrupt on the DP Master SFC 9 EN_MSG COM_FUNC Enable Block-Related, Symbol-Related and Group Status Messages SFC 10 DIS_MSG COM_FUNC Disable Block-Related, Symbol-Related and Group Status Messages SFC 11 DPSYC_FR DP Synchronize Groups of DP Slaves SFC 12 D_ACT_DP DP Deactivation and activation of DP slaves SFC 13 DPNRM_DG DIAGNSTC Read Diagnostic Data of a DP Slave (Slave Diagnostics) SFC 14 DPRD_DAT DP Read Consistent Data of a Standard DP Slave SFC 15 DPWR_DAT DP Write Consistent Data to a DP Standard Slave SFC 17 ALARM_SQ PMC_FUNC Generate Acknowledgeable Block-Related Messages SFC 18 ALARM_S PMC_FUNC Generate Permanently Acknowledged Block-Related Messages SFC 19 ALARM_SC PMC_FUNC Query the Acknowledgment Status of the last ALARM_SQ Entering State Message SFC 20 BLKMOV MOVE Copy Variables SFC 21 FILL MOVE Initialize a Memory Area SFC 22 CREAT_DB DB_FUNCT Create Data Block SFC 23 DEL_DB DB_FUNCT Delete Data Block SFC 24 TEST_DB DB_FUNCT Test Data Block SFC 25 COMPRESS DB_FUNCT Compress the User Memory SFC 26 UPDAT_PI IO_FUNCT Update the Process Image Update Table SFC 27 UPDAT_PO IO_FUNCT Update the Process Image Output Table SFC 28 SET_TINT PGM_CNTL Set Time-of-Day Interrupt SFC 29 CAN_TINT PGM_CNTL Cancel Time-of-Day Interrupt SFC 30 ACT_TINT PGM_CNTL Activate Time-of-Day Interrupt SFC 31 QRY_TINT PGM_CNTL Query Time-of-Day Interrupt SFC 32 SRT_DINT PGM_CNTL Start Time-Delay Interrupt SFC 33 CAN_DINT PGM_CNTL Cancel Time-Delay Interrupt SFC 34 QRY_DINT PGM_CNTL Query Time-Delay Interrupt SFC 35 MP_ALM PGM_CNTL Trigger Multicomputing Interrupt SFC 36 MSK_FLT DIAGNSTC Mask Synchronous Errors SFC 37 DMSK_FLT DIAGNSTC Unmask Synchronous Errors SFC 38 READ_ERR DIAGNSTC Read Error Register SFC 39 DIS_IRT IRT_FUNC Disable New Interrupts and Asynchronous Errors SFC 40 EN_IRT IRT_FUNC Enable New Interrupts and Asynchronous Errors SFC 41 DIS_AIRT IRT_FUNC Delay Higher Priority Interrupts and Asynchronous Errors SFC 42 EN_AIRT IRT_FUNC Enable Higher Priority Interrupts and Asynchronous Errors SFC 43 RE_TRIGR PGM_CNTL Re-trigger Cycle Time Monitoring SFC 44 REPL_VAL DIAGNSTC Transfer Substitute Value to Accumulator 1 SFC 46 STP PGM_CNTL Change the CPU to STOP SFC 47 WAIT PGM_CNTL Delay Execution of the User Program SFC 48 SNC_RTCB CLK_FUNC Synchronize Slave Clocks SFC 49 LGC_GADR IO_FUNCT Query the Module Slot Belonging to a Logical Address SFC 50 RD_LGADR IO_FUNCT Query all Logical Addresses of a Module SFC 51 RDSYSST DIAGNSTC Read a System Status List or Partial List SFC 52 WR_USMSG DIAGNSTC Write a User-Defined Diagnostic Event to the Diagnostic Buffer SFC 54 RD_PARM IO_FUNCT Read Defined Parameters SFC 55 WR_PARM IO_FUNCT Write Dynamic Parameters SFC 56 WR_DPARM IO_FUNCT Write Default Parameters SFC 57 PARM_MOD IO_FUNCT Assign Parameters to a Module SFC 58 WR_REC IO_FUNCT Write a Data Record SFC 59 RD_REC IO_FUNCT Read a Data Record SFC 60 GD_SND COM_FUNC Send a GD Packet SFC 61 GD_RCV COM_FUNC Fetch a Received GD Packet SFC 62 CONTROL COM_FUNC Query the Status of a Connection Belonging to a Communication SFB Instance SFC 63 AB_CALL PLASTICS Assembly Code Block (only exists for CPU 614) SFC 64 TIME_TCK CLK_FUNC Read the System Time SFC 65 X_SEND COM_FUNC Send Data to a Communication Partner outside the Local S7 Station SFC 66 X_RCV COM_FUNC Receive Data from a Communication Partner outside the Local S7 Station SFC 67 X_GET COM_FUNC Read Data from a Communication Partner outside the Local S7 Station SFC 68 X_PUT COM_FUNC Write Data to a Communication Partner outside the Local S7 Station SFC 69 X_ABORT COM_FUNC Abort an Existing Connection to a Communication Partner outside the Local S7 Station SFC 70 GEO_LOG IO_FUNCT Determine Start Address of a Module SFC 71 LOG_GEO IO_FUNCT Determine the Slot Belonging to a Logical Address SFC 72 I_GET COM_FUNC Read Data from a Communication Partner within the Local S7 Station SFC 73 I_PUT COM_FUNC Write Data to a Communication Partner within the Local S7 Station SFC 74 I_ABORT COM_FUNC Abort an Existing Connection to a Communication Partner within the Local S7 Station SFC 78 OB_RT DIAGNSTC Determine OB program runtime SFC 79 SET BIT_LOGC Set a Range of Outputs SFC 80 RSET BIT_LOGC Reset a Range of Outputs SFC 81 UBLKMOV MOVE Uninterruptible Block Move SFC 82 CREA_DBL DB_CTRL Create a Data Block in the Load Memory SFC 83 READ_DBL DB_CTRL Read from a Data Block in Load Memory SFC 84 WRIT_DBL DB_CTRL Write from a Data Block in Load Memory SFC 85 CREA_DB DB_FUNCT Create a Data Block SFC 87 C_DIAG COM_FUNC Diagnosis of the Actual Connection Status SFC 90 H_CTRL HF_FUNCT Control Operation in H Systems SFC 100 SET_CLKS CLK_FUNC Setting the Time-of-Day and the TOD Status SFC 101 RTM CLK_FUNC Handling runtime meters SFC 102 RD_DPARA IO_FUNCT Redefined Parameters SFC 103 DP_TOPOL DP Identifying the bus topology in a DP master system SFC 104 CIR PGM_CNTL Controlling CiR SFC 105 READ_SI PMC_FUNC Reading Dynamic System Resources SFC 106 DEL_SI PMC_FUNC Deleting Dynamic System Resources SFC 107 ALARM_DQ PMC_FUNC Generating Always Acknowledgeable and Block-Related Messages SFC 108 ALARM_D PMC_FUNC Generating Always Acknowledgeable and Block-Related Messages SFC 112 PN_IN PROFIne2 Update inputs in the user program interface of PROFInet components SFC 113 PN_OUT PROFIne2 Update outputs in the user program interface of PROFInet components SFC 114 PN_DP PROFIne2 Update DP interconnections SFC 126 SYNC_PI IO_FUNCT Update process image partition input table in synchronous cycle SFC 127 SYNC_PO IO_FUNCT Update process image partition output table in synchronous cycle
S5-S7 Converting Blocks Number Name Family Description FC 61 GP_FPGP S5_CNVRT Change fixed point number to floating point number FC 62 GP_GPFP S5_CNVRT Change floating point number to fixed point number FC 63 GP_ADD S5_CNVRT Add floating point numbers FC 64 GP_SUB S5_CNVRT Subtract floating point numbers FC 65 GP_MUL S5_CNVRT Multiply floating point number FC 66 GP_DIV S5_CNVRT Divide floating point numbers FC 67 GP_VGL S5_CNVRT Compare floating point numbers FC 68 RAD_GP S5_CNVRT Extract root of floating point numbers FC 69 MLD_TG S5_CNVRT Clock generator FC 70 MLD_TGZ S5_CNVRT Clock generator (timing element) FC 71 MLD_EZW S5_CNVRT Message of first value with single flashing light, wordwise, A FC 72 MLD_EDW S5_CNVRT Message of first value with double flashing light, wordwise, A FC 73 MLD_SAMW S5_CNVRT Collected message, wordwise (sound alert) FC 74 MLD_SAM S5_CNVRT Collected message, bitwise FC 75 MLD_EZ S5_CNVRT Message of first value with single flashing light, bitwise, A FC 78 MLD_EDWK S5_CNVRT Message of first value with double flashing light, wordwise, A+M FC 79 MLD_EZK S5_CNVRT Message of first value with single flashing light, bitwise, A+M FC 80 MLD_EDK S5_CNVRT Message of first value with double flashing light, bitwise, A+M FC 81 COD_B4 S5_CNVRT Change BCD number to 16 bit dual number FC 82 COD_16 S5_CNVRT Change 16 bit dual number to BCD number FC 83 MUL_16 S5_CNVRT Multiply 16 bit dual numbers FC 84 DIV_16 S5_CNVRT Divide 16 bit dual numbers FC 85 ADD_32 S5_CNVRT Add 32 bit dual numbers FC 86 SUB_32 S5_CNVRT Subtract 32 bit dual numbers FC 87 MUL_32 S5_CNVRT Multiply 32 bit dual numbers FC 88 DIV_32 S5_CNVRT Divide 32 bit dual numbers FC 89 RAD_16 S5_CNVRT Extract roots of 16 bit dual numbers FC 90 REG_SCHB S5_CNVRT Bi-directional shift register, bitwise FC 91 REG_SCHW S5_CNVRT Bi-directional shift register, wordwise FC 92 REG_FIFO S5_CNVRT Buffer memory (FIFO) FC 93 REG_LIFO S5_CNVRT Stack register (LIFO) FC 94 DB_COPY1 S5_CNVRT Copy data block, direct assignment of parameters FC 95 DB_COPY2 S5_CNVRT Copy data block, indirect assignment of parameterization FC 96 RETTEN S5_CNVRT Save scratchpad memory FC 97 LADEN S5_CNVRT Load scratchpad memory FC 98 COD_B8 S5_CNVRT Change BCD number to 32 bit dual number FC 99 COD_32 S5_CNVRT Change 32 bit dual number to BCD number FC 100 AE_460_1 S5_CNVRT Read analog value FC 101 AE_460_2 S5_CNVRT Read analog value FC 102 AE_463_1 S5_CNVRT Read analog value FC 103 AE_463_2 S5_CNVRT Read analog value FC 104 AE_464_1 S5_CNVRT Read analog value FC 105 AE_464_2 S5_CNVRT Read analog value FC 106 AE_466_1 S5_CNVRT Read analog value FC 107 AE_466_2 S5_CNVRT Read analog value FC 108 RLG_AA1 S5_CNVRT Output analog value FC 109 RLG_AA2 S5_CNVRT Output analog value FC 110 PER_ET1 S5_CNVRT Read and Write for extended periphery (direct assignment of parameters) FC 111 PER_ET2 S5_CNVRT Read and Write for extended periphery (indirect assignment of parameters) FC 112 SINUS S5_CNVRT Sine (x) FC 113 COSINUS S5_CNVRT Cosine (x) FC 114 TANGENS S5_CNVRT Tangent (x) FC 115 COTANG S5_CNVRT Cotangent (x) FC 116 ARCSIN S5_CNVRT Arc sine (x) FC 117 ARCCOS S5_CNVRT Arc cosine (x) FC 118 ARCTAN S5_CNVRT Arc tangent (x) FC 119 ARCCOT S5_CNVRT Arc cotangens (x) FC 120 LN_X S5_CNVRT Natural logarithm ln (x) FC 121 LG_X S5_CNVRT Decade logarithm Iog (x) FC 122 B_LOG_X S5_CNVRT General logarithm log (x) to basis b FC 123 E_H_N S5_CNVRT e to the power of n FC 124 ZEHN_H_N S5_CNVRT 10 to the power of n FC 125 A2_H_A1 S5_CNVRT AKKU 2 to the power of AKKU 1
IEC Function Blocks Number Name Family Description FC 1 AD_DT_TM IEC Point Math Add duration to a time FC 2 CONCAT IEC Combine two STRING variables FC 3 D_TOD_DT IEC Combine DATE and TIME_OF_DAY to DT FC 4 DELETE IEC Delete in a STRING variable FC 5 DI_STRNG IEC Data type conversion DINT to STRING FC 6 DT_DATE IEC Extract the DATE from DT FC 7 DT_DAY IEC Extract the day of the week from DT FC 8 DT_TOD IEC Extract the TIME_OF_DAY from DT FC 9 EQ_DT IEC Compare DT for equal FC 10 EQ_STRNG IEC Compare STRING for equal FC 11 FIND IEC Find in a STRING variable FC 12 GE_DT IEC Compare DT for greater than or equal FC 13 GE_STRNG IEC Compare STRING for greater than or equal FC 14 GT_DT IEC Compare DT for greater than FC 15 GT_STRNG IEC Compare STRING for greater than FC 16 I_STRNG IEC Data type conversion INT to STRING FC 17 INSERT IEC Insert in a STRING variable FC 18 LE_DT IEC Compare DT for smaller than or equal FC 19 LE_STRNG IEC Compare STRING for smaller than or equal FC 20 LEFT IEC Left part of a STRING variable FC 21 LEN IEC Length of a STRING variable FC 22 LIMIT IEC Point Math Limit FC 23 LT_DT IEC Compare DT for smaller than FC 24 LT_STRNG IEC Compare STRING for smaller than FC 25 MAX IEC Point Math Select maximum FC 26 MID IEC Middle part of a STRING variable FC 27 MIN IEC Point Math Select minimum FC 28 NE_DT IEC Compare DT for unequal FC 29 NE_STRNG IEC Compare STRING for unequal FC 30 R_STRNG IEC Data type conversion REAL to STRING FC 31 REPLACE IEC Replace in a STRING variable FC 32 RIGHT IEC Right part of a STRING variable FC 33 S5TI_TIM IEC Data type conversion S5TIME to TIME FC 34 SB_DT_DT IEC Point Math Subtract two time values FC 35 SB_DT_TM IEC Point Math Subtract duration from a time FC 36 SEL IEC Point Math Binary selection FC 37 STRNG_DI IEC Data type conversion STRING to DINT FC 38 STRNG_I IEC Data type conversion STRING to INT FC 39 STRNG_R IEC Data type conversion STRING to REAL FC 40 TIM_S5TI IEC Data type conversion TIME to S5TIME
PID Control Blocks Number Name Family Description FB 41 CONT_C ICONT Continuous Control FB 42 CONT_S ICONT Step Control FB 43 PULSEGEN ICONT Pulse Generation FB 58 TCONT_CP CONTROL Temperature Continuous Controller FB 59 TCONT_S CONTROL Temperature Step Controller
Communication Blocks Number Name Family Description FB 2 IDENTIFY CP_300 For checking device properties FB 3 READ CP_300 Reads data from a data area of the communication partner specified by a name or index depending on the assignment of parameters for the job. FB 4 REPORT CP_300 Allows unconfirmed transmission of variables by an FMS server. FB 5 STATUS CP_300 allows status information to be requested from the communications partner on the specified FMS connection. FB 6 WRITE CP_300 Transfers data from a specified local data area to a data area on the communication partner. FB 8 USEND CP_300 Uncoordinated Sending of Data FB 9 URCV CP_300 Uncoordinated Receiving of Data FB 12 BSEND CP_300 Sending Segmented Data FB 13 BRCV CP_300 Receiving Segmented Data FB 14 GET CP_300 Read Data from a Remote CPU FB 15 PUT CP_300 Write Data to a Remote CPU FB 20 GETIO IO_FUNCT Read All Inputs of a DP Standard Slave/PROFINET IO Device FB 21 SETIO IO_FUNCT Write All Outputs of a DP Standard Slave/PROFINET IO Device FB 22 GETIO_PART IO_FUNCT Read a Part of the Inputs of a DP Standard Slave/PROFINET IO Device FB 23 SETIO_PART IO_FUNCT Write a Part of the Outputs of a DP Standard Slave/PROFINET IO Device FB 55 IP_CONFIG CP_300 Transfers a configuration data block (CONF_DB) containing connection data for an Ethernet CP. FB 63 TSEND COMM Sending Data via TCP native and ISO on TCP FB 64 TRCV COMM Receiving Data via TCP native and ISO on TCP FB 65 TCON COMM Establishing a Connection using TCP native and ISO on TCP FB 66 TDISCON COMM Terminating a Connection using TCP native and ISO on TCP FB 67 TUSEND COMM Sending Data via UDP FB 68 TURCV COMM Receiving Data via UDP FC 1 DP_SEND CP_300 transfers data to the PROFIBUS CP FC 2 DP_RECV CP_300 receives data on PROFIBUS FC 3 DP_DIAG CP_300 used to request diagnostic information FC 4 DP_CTRL CP_300 transfers control jobs to the PROFIBUS CP FC 5 AG_SEND CP_300 data by means of a configured connection to the communication partner (<= 240 bytes). FC 6 AG_RECV CP_300 data by means of a configured connection from the communication partner (<= 240 bytes, not email). FC 7 AG_LOCK CP_300 the external data access by means of FETCH/WRITE (not for UDP, email). FC 8 AG_UNLOCK CP_300 the external data access by means of FETCH/WRITE (not for UDP, email). FC 10 AG_CNTRL CP_300 allows you to diagnose connections. When necessary, you can reinitialize connection establishment using the FC. FC 11 PNIO_SEND CP_300 used for data transfer in the CP modes PROFINET IO controller or PROFINET IO device. FC 12 PNIO_RECV CP_300 used to receive data in the CP modes PROFINET IO controller or PROFINET IO device. FC 40 FTP_CONNECT CP_300 Establish an FTP connection FC 41 FTP_STORE CP_300 Store a file on the FTP server FC 42 FTP_RETRIEVE CP_300 Retrieve a file from the FTP server FC 43 FTP_DELETE CP_300 Delete a file on the FTP server FC 44 FTP_QUIT CP_300 Enable an FTP connection FC 50 AG_LSEND CP_300 data by means of a configured connection to the communication partner. FC 60 AG_LRECV CP_300 data by means of a configured connection from the communication partner (not email). FC 62 C_CNTRL CP_300 Query a connection status for S7-300
TI-S7 Converting Blocks Number Name Family Description FB 80 LEAD_LAG CONVERT Lead/Lag Algorithm FB 81 DCAT TIMERS Discrete Control Alarm Timer FB 82 MCAT TIMERS Motor Control Alarm Timer FB 83 IMC COMPARE Index Matrix Compare FB 84 SMC COMPARE Scan Matrix Compare FB 85 DRUM TIMERS Event Maskable Drum FB 86 PACK MOVE Pack Data FC 80 TONR TIMERS Software Timer On Delay—Retentive FC 81 IBLKMOV MOVE Indirect Block Move FC 82 RSET BIT_LOGC Reset Range of Outputs FC 83 SET BIT_LOGC Set Range of Outputs FC 84 ATT TABLE Add to Table FC 85 FIFO TABLE First In/First Out Unload Table FC 86 TBL_FIND TABLE Table Find FC 87 LIFO TABLE Last In/First Out Unload Table FC 88 TBL TABLE Table FC 89 TBL_WRD TABLE Move Table to Word FC 90 WSR SHIFT Word Shift Register FC 91 WRD_TBL TABLE Word to Table FC 92 SHRB SHIFT Bit Shift Register FC 93 SEG CONVERT Seven Segment Decoder FC 94 ATH CONVERT ASCII to Hex FC 95 HTA CONVERT Hex to ASCII FC 96 ENCO CONVERT Encode Binary Position FC 97 DECO CONVERT Decode Binary Position FC 98 BCDCPL CONVERT Ten’s Complement FC 99 BITSUM CONVERT Sum Number of Bits FC 100 RSETI BIT_LOGC Reset Range of Immediate Outputs FC 101 SETI BIT_LOGC Set Range of Immediate Outputs FC 102 DEV MATH_FP Standard Deviation FC 103 CDT TABLE Correlated Data Table FC 104 TBL_TBL TABLE Table to Table FC 105 SCALE CONVERT Scaling Values FC 106 UNSCALE CONVERT Unscaling Values
Miscellaneous Blocks Number Name Family Description FB 60 SET_SW TIMEFUNC supports the summertime/wintertime changeover in CPUs that do not have the time status. For this purpose it sets the CPU clock to the current time and according to the changeover rules in the Control DB. FB 61 SET_SW_S TIMEFUNC supports the summertime/wintertime changeover in CPUs that do have the time status. For this purpose it sets the time status to the current time and according to the changeover rules in the Control DB. FB 62 TIMESTMP TIMEFUNC transfers the time-stamped messages of an IM153-2 into its instance DB. FC 60 LOC_TIME TIMEFUNC reads the time status or time of the CPU and calculates the local time. It is therefore only useful on CPUs with time status. FC 61 BT_LT TIMEFUNC calculates the local time from the base time given at the input. FC 62 LT_BT TIMEFUNC calculates the base time from the local time given at the input. FC 63 S_LTINT TIMEFUNC sets the required time interrupt to the preset time. This time is given in local time.
| |
|
NERO92 جندي
عدد الرسائل : 3 العمر : 32 تاريخ التسجيل : 10/12/2010
| موضوع: رد: جدولة كاملة لبلوكات الوظائف الخاصة في s7-300 الجمعة 10 ديسمبر 2010 - 14:37 | |
| شكراً لك أخي على هذا الموضوع القيم | |
|
الفقير لله لواء
عدد الرسائل : 1846 العمر : 42 الموقع : ارض السواد تاريخ التسجيل : 08/04/2010
| موضوع: رد: جدولة كاملة لبلوكات الوظائف الخاصة في s7-300 الجمعة 10 ديسمبر 2010 - 20:23 | |
| بصراحه اخي مساهمه قيمه شكرا لك | |
|
mostafasadek79 لواء
عدد الرسائل : 1237 العمر : 45 الموقع : مصر العمل/الترفيه : Automation Engineer تاريخ التسجيل : 04/09/2010
| موضوع: رد: جدولة كاملة لبلوكات الوظائف الخاصة في s7-300 الجمعة 21 يناير 2011 - 11:27 | |
| شكراً لك _________________ | |
|